The right air purifier should be sized by room volume and clean-air delivery rate, not floor area alone.
CADR, or Clean Air Delivery Rate, tells you how much filtered air the purifier can deliver over time. A higher CADR generally means the purifier can clean a larger room or circulate the room air more frequently. For most homes, it is more useful to think in terms of both CADR and air changes per hour (ACH) rather than relying only on a claimed coverage area.
A practical calculation is:
Required CADR = Room Area × Ceiling Height × Target ACH
For example, a 20 m² bedroom with a 2.5 m ceiling has a volume of 50 m³. At 4 ACH, the required CADR is about 200 m³/h.
For a normal residential room, CADR should increase as room volume increases.
Using a 2.5 m ceiling and approximately 4 ACH as a practical reference:
| Room Size | Room Volume | Suggested CADR |
|---|---|---|
| 10 m² | 25 m³ | Around 100 m³/h |
| 15 m² | 37.5 m³ | Around 150 m³/h |
| 20 m² | 50 m³ | Around 200 m³/h |
| 30 m² | 75 m³ | Around 300 m³/h |
| 40 m² | 100 m³ | Around 400 m³/h |
INVITOP currently offers air purifiers across a wide CADR range, from compact models around 95–120 m³/h to larger systems reaching 800–1000 m³/h, allowing different room sizes to be matched more closely to actual airflow requirements. For further sizing advice, refer to the EPA’s guide to selecting a portable air cleaner.
Not necessarily.
A higher CADR means faster particle removal, but selecting the largest available unit for a small room can add unnecessary cost, size, noise, and power consumption.
The better question is whether the purifier can achieve the required number of air changes at a fan speed that is practical for everyday use.
This point matters because CADR is normally measured at a high or maximum operating speed. A purifier that technically meets the room requirement only at its loudest setting may be less suitable for a bedroom than a slightly larger model that can achieve adequate airflow at a quieter speed. EPA notes that CADR ratings are typically measured at the air cleaner's highest speed.
ACH describes how many times the equivalent volume of air in a room is cleaned within one hour.
For general household use, around 3–4 ACH is a useful sizing range. Where faster particle removal is needed, buyers may choose a higher target.
For example:
A 30 m² living room with a 2.5 m ceiling contains 75 m³ of air.
At 4 ACH:
75 × 4 = 300 m³/h CADR
This is why two purifiers with the same advertised room coverage may not perform equally. One manufacturer may base coverage on a lower air-change rate, while another may use a more demanding assumption.
For this reason, CADR is usually a more useful comparison point than room coverage alone.

Yes.
Room area only measures the floor. The purifier has to clean the entire volume of air above it.
A 20 m² room with a 2.4 m ceiling contains 48 m³ of air, while the same floor area with a 3.2 m ceiling contains 64 m³. That is about one-third more air to process.
EPA specifically advises considering a higher CADR when ceiling height exceeds the standard assumptions used in room-size recommendations.
For open-plan homes, connected living and dining areas should also be treated as one larger air volume rather than sizing the purifier only for the section where it is physically placed.
No. CADR measures clean-air delivery performance, not filtration technology by itself.
A purifier with a good CADR still needs an appropriate filtration system for the pollutant being targeted.
For particles such as dust, pollen, and PM2.5, HEPA filtration is important. For gases, odors, and some VOCs, activated carbon or another adsorbent media is required. EPA notes that particle filters and gas filters address different pollutant types, which is why many air cleaners combine both.
This is an important part of air purifier design: airflow and filtration efficiency must be balanced. A highly restrictive filter can reduce airflow if the fan system is not engineered to compensate, while very high airflow with poor filtration will not provide effective particle removal.
CADR reflects the result of both factors working together.
The current INVITOP air purifier range covers compact and high-capacity applications.
For smaller rooms, models such as Jupiter and Zoro air purifier offer CADR values around 95–105 m³/h. Mid-range models such as Mercury, Ganymede, Mars, Jupiter Plus and the Zoe Plus air purifier cover approximately 200–375 m³/h, while larger models such as Neptune and Scuti reach substantially higher airflow levels.
For example, the Neptune model provides a CADR of 600 m³/h and is listed for spaces up to approximately 72 m².
The correct model still depends on the desired ACH, ceiling height, pollution level, and acceptable operating noise.
For distributors sourcing from a home air purifier factory, CADR should be evaluated together with:
Filter configuration.
Check whether the system targets particles only or also includes activated carbon or additional treatment stages.
Noise at usable fan speeds.
Bedroom products need different acoustic priorities from large living-room models.
Sensor accuracy and automatic control.
PM2.5, TVOC, temperature, and humidity sensing can improve automatic operation when properly calibrated.
Filter replacement interval and cost.
Long-term ownership cost can influence retail acceptance as much as initial product price.
Air outlet and intake layout.
Good airflow distribution can help reduce stagnant zones in real rooms.
These factors help explain why two products with similar CADR values can deliver different user experiences.
Choosing an air purifier by room size is useful, but room volume, CADR, and target ACH provide a much more reliable sizing method.
Measure the room, include ceiling height, decide how frequently you want the air cleaned, and then select a purifier with enough CADR to meet that target.
For most homes, choosing slightly above the calculated minimum can provide quieter operation and additional capacity when air quality worsens.
INVITOP offers air purifier platforms from compact household units to high-CADR models for larger rooms, giving distributors and OEM/ODM buyers flexibility to match product performance to different residential applications.
For many bedrooms, roughly 100–250 m³/h can be appropriate, depending on room volume and the desired air-change rate.
A higher CADR can remove airborne particles faster, provided the purifier also uses an effective particle filter.
Yes. An undersized unit may run continuously while still providing too few air changes per hour.
Yes, but calculate the entire connected air volume rather than only the area immediately around the purifier.
They measure different things. HEPA describes filtration efficiency, while CADR indicates how much clean air the complete purifier delivers.